-40%

MPPT 60A/40A/30A/20A Solar Charge Controller 12V 24V 36V 48V Battery Regulator

$ 7.38

Availability: 71 in stock
  • Features: Indicator Light, LCD Display, Portable
  • Protection Properties: Discharge Protection, Overcharge Protection, Overcurrent Protection, Overload Protection
  • Current Output: 60A/40A/30A/20A
  • Voltage: 12V/2V/36V/48V
  • Inverter Technology: Hybrid
  • System Configuration: Hybrid
  • Color: 60A 12V/24V/36V/48V
  • Pliability: Flexible
  • Charging Mode: MPPT (Maximum Power Point Tracking)
  • Current Type: DC
  • Condition: New
  • Brand: EASUN
  • Type: Solar Charge Controller
  • Power Source: Solar
  • Maximum Input Voltage: 12V/24V/36V/48V

    Description

    FEATURE
    Charging 3-stage: constant current(MPPT), constant voltage(Absorption Voltage), floating charge
    Selectable battery type Vented / Sealed / Gel / NiCd / Lithium battery (default is Sealed) (defined voltage for other battery by user)
    Soft start time ≤1S, Dynamic response and recovery time 100us
    Max efficiency ≥98.1%, PV utilization ≥99%
    In order to reduce the cost of electricity caused by high current, PV and battery each have two terminals
    MULTIPLE ELECTRONIC PROTECTIONS
    Short-circuting
    Reverse-current
    Overcharging
    Overload
    Over-discharging
    Reverse polarity protection
    Maximum PV Input Power
    Ensure that the solar input voltage exceeds 3v or is higher than the battery voltage.
    12 Volt Battery Systems: Maximum PV input power 720 watts, recommended solar input voltage range 20 - 80 volts DC.
    24 Volt Battery Systems: Maximum PV input power 1440 watts, recommended PV input voltage range 37 - 105 VDC
    36 volt battery system: 2100 watt maximum PV input, recommended PV input voltage range 50 - 150 volts DC
    48 volt battery system: 2800 watt maximum PV input, recommended PV input voltage range 72 - 150 volts DC
    Installation Procedure
    Installation Procedure
    Install the switch between the controller and the battery.
    Install a switch between the controller and the PV module.
    Check that the "+" and "-" of the PV module and the "+" and "-" of the battery are correctly connected.
    Turn on the battery switch first, then turn on the PV switch.
    LCD display
    ESC: Exit the setting without saving the data.
    UP: Scroll down, adjust the parameter by increasing the value.
    DOWN: Scroll up, adjust the parameter by decreasing the value.
    ENTER: Short press to move to the next setting page, long press to exit the setting and save the data.
    Display Code Meaning
    Display Code Meaning
    EQU: Load voltage compensation
    BST: Pulse charging voltage
    FLD: Load voltage hold
    LDV: Over-discharge voltage
    LRV: Over-discharge recovery voltage
    BST - r: Pulse charge recovery voltage
    Battery type: FLD/SEL/Gel/Lithium/Use
    Warning and Caution
    1. the battery voltage must be higher than 12v for the controller to start.
    2. make sure that the solar input voltage exceeds 3v or the battery voltage. 3. hold the wiring correctly and do not change the wiring.
    3. hold the wiring correctly and do not change the wiring. pay attention to the order of the terminal wiring.
    4. if it is a lead acid battery, if it is not professional, do not set any parameter, because in addition to the lithium battery, the controller also works well in the standard state.
    5. do not connect solar inverters / generators / wind turbines to the controller.
    6. Install the controller indoors to prevent the components from entering the water.
    7.Maximum PV input voltage (voc): 180 V dc, the controller cannot work for a long time under this voltage, which will damage the controller.
    8. Disconnect the battery and reconnect to save the configuration.
    40A 30A 20A MPPT solar charge controller(Fan cooling)
    12V/24V(auto detection);32V(setting)
    MPPT efficiency>99%,Peak conversion
    efficiency >98%
    DSP processors technology ensure high
    speed and performance
    Multi-stage charging mode
    Protection: PV array short circuit ,
    PV reverse polarity , Battery reverse polarity ,
    Over charging , Output short circuit
    Equalization charging function
    BTS function
    Models
    ICharer MPPT 2420 2430 2440
    Rated charge current
    20A/30A/40A
    System Voltage
    12/24V Auto recognized
    Max PV Input Power
    260W(12V) 260W(12V)/ 260W(12V) 260W(12V)/520W(12V)
    1040W (24V)
    Solar panel inputrange
    16.8V-60V(12V) 33.6V-
    60V
    (24V) /16.8V-60V(12V) 33.6V-60V(24V)/16.8V-60V(12V)33.6V-60V(24V)
    BatteryVoltageAutom
    aticRecognition
    12VSystem(DC8.7V-DC15.SV)24VSystem(DC16V-DC31V)
    36VSystem(DC33V-DC41V)48VSystem(DC42V-DC64V)
    Maximum batteryvoltage
    8V-32V
    Battery type
    Battery type
    LVD
    Maintenance-free lead-acid battery, GEL, lead-acid Flooded battery :10.8V
    LVR
    Maintenance-free lead-acid battery, GEL, lead-acid Flooded battery :12.6V
    HVD
    Lead acid battery 16V
    Temperature compensationcoefficient
    -4mV/°C/2V(25°C)
    Fan-onTemperature
    >45

    Fan-offTemperature
    <40

    Size(mm)
    247.3*201*80.3
    NeWteight(Kg)
    1.5
    Light control voltage
    ≤90%, No condensation
    Enclosure
    IP30
    Opertation Temperature
    -20°C~

    55°C
    Storage Temperature
    -30°C~

    70°C