-40%

EPEVER 30A MPPT Solar Charge Controller 12/24V Auto Solar Panel Max PV 100V

$ 63.35

Availability: 81 in stock
  • Return shipping will be paid by: Buyer
  • Power Source: Solar
  • Power: Under 780W
  • Maximum Input Voltage: Under 100 V
  • Condition: New
  • Voltage: 12/24V
  • Current Type: DC
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • System Configuration: Off-Grid
  • Brand: Epever
  • Application: Agriculture/Farming
  • Type: Solar Charge Controller
  • Model: Triron3210N
  • Restocking Fee: No
  • Maximum Input Power: Less Than 780 W
  • Current Rating: 30 A
  • Charging Mode: MPPT (Maximum Power Point Tracking)

    Description

    EPEVER  MPPT Solar Charge Controller 30A ,12V/24V Auto Work ,Max PV 100V solar panel Input Common Negative Grounding with LCD Display Suitable for Lead-Acid (Sealed /GEL/AGM/Flooded ) and Lithium type Batteries
    Specification:
    Triron321
    0
    N:
    Rated charge and discharge current: 30A (12V/24V Auto Work)
    Max. PV input power: 39
    0W
    solar panels for 12V batteries system or 780
    W solar panels
    for 24V batteries system
    Suitable battery types: Sealed /GEL/AGM/Flooded / lithium-ion (USER)
    Battery voltage range: 8V~32V
    Max. PV open circuit voltage: 100VDC
    Terminal: 6AWG(16mm2 )
    Recommended cable:6AWG(16mm2)
    (We have warehouse located in Chicago IL U.S.A, supply on-time shipping and local afterslae services .
    )
    No matter what problems you encounter in the process of purchase or use, our strong after-sales service team will serve you wholeheartedly. Feel free to contact us by eBay message.
    [
    Note
    ]
    Please read the instruction manual carefully or consult customer service to avoid damage to the new controller due to improper operation. The flooded battery must be place in a well ventilated space to avoid any possible danger or explosion. And please make sure that the positive and negative terminals of each component are wired correctly.
    The
    TRIRON-N
    series MPPT controllers are modular-designed products based on nine MPPT solar controller models. The main unit (Power Module) is a solar controller which can be integrated with different display and interface modules to meet a variety of functional requirements. Among them,
    t
    he
    master and slave interface module can synchronize and view the controller and inverter operating data on the LCD.
    Optimizing the MPPT control algorithm further to ensure minimum power point loss rate and loss time, and quickly track the maximum power point to obtain the maximum solar energy of PV array in any environment. Meanwhile,TRIRON controller adds automatic limit function of charging power and current, so that the controller would not be damaged even connecting oversized PV modules (the
    actual working value would not be higher than rated value).
    The controller adopts the three-stage charging mode, and has perfect electronic protection function, which can effectively extend the battery life, improve the system performance, and ensure the system safety, stability and long-term operation. TRIRION controller can be widely used in RV, telecommunication base station, household system,field monitoring, etc.
    Product Features

    Self-identifying, load the driver for each module

    Support the hot swapping function(only for same model)

    Advanced MPPT control algorithm to minimize the MPP loss rate and loss time

    Modular design, varied combination to meet different requirements

    Ultra-fast tracking speed, and high tracking efficiency ≥99.5%

    Accurately tracking and recognizing of multiple MPP

    Peak conversion efficiency of 98%

    Auto limit function of charging power and charging current

    Compatible with lead-acid batteries and lithium batteries

    Wide MPP operating voltage range

    Full load operation during the working temperature range

    Auto reduce power function when charging in high temperature

    Multiple load work modes

    Battery temperature compensation

    Real-time power statistics recording function

    Multiple LCD and LED display modules optional

    Master-slave interface module design,simultaneously view the controller and inverter operating data

    Dry contact design, remotely switch on/off external equipment

    Dual USB design, supply DC power for electronic equipment

    Perfect electronic protection function
    Protection function

    PV over current protection

    PV short circuit protection

    Lithium battery low temperature protection

    Night reverse charging protection

    Battery reverse polarity protection

    PV reverse polarity protection

    Battery over discharge protection

    Battery over heat protection

    Battery over voltage protection

    Load short circuit protection

    Load overload protection

    Controller overheating protection
    Electrical parameters
    Model
    TRIRON 1210N
    TRIRON 2210N
    TRIRON 3210N
    TRIRON 4210N
    Nominal system voltage
    12/24VDC auto work
    Rated charge current
    10A
    20A
    30A
    40A
    Rated discharge current
    10A
    20A
    30A
    40A
    Battery input voltage range
    8~32V
    Max. PV open circuit voltage
    TRIRON**10N : 100Vat Min operating environment temp; 92Vat 25℃environment temp
    TRIRON**15N :100Vat Min operating environment temp; 138Vat 25℃environment temp
    MPP voltage range
    TRIRON**10N : (Vbat+2V)~72V
    TRIRON**15N : (Vbat+2V)~92V
    Max.PV input power
    130W/12V
    260W/24V
    260W/12V
    520W/24V
    390W/12V
    780W/24V
    520W/12V
    1040W/24V
    Battery type
    Sealed / Gel / Flooded;LiFePO4 / Li-NiCoMn / User
    Lithium battery(LiFePO4 /Li-NiCoMn/User)
    ◆ Lead-acid batteries
    Equalize charging voltage
    Sealed: 14.6V, Flooded: 14.8V,
    User-defined: 9~17V
    Boost charging voltage
    Gel: 14.2V, Sealed: 14.4V, Flooded: 14.6V,
    User-defined: 9~17V
    Float charging voltage
    Gel /Sealed /Flooded: 13.8V,
    User-defined: 9~17V
    Low voltage reconnect voltage
    Gel /Sealed /Flooded: 12.6V,
    User-defined: 9~17V
    Low voltage disconnect voltage
    Gel /Sealed /Flooded: 11.1V,
    User-defined: 9~17V
    ◆ Li-battery
    Boost charging voltage
    LiFePO4:14.4V;Li-NiCoMn:12.4V;
    User:9-17V
    Float charging voltage
    LiFePO4: 13.6V;Li-NiCoMn:11.8V;
    User:9-17V
    Low voltage reconnect voltage
    LiFePO4:12.4V;Li-NiCoMn:10.40V;
    User:9-17V
    Low voltage disconnect voltage
    LiFePO4:11.0V;Li-NiCoMn:9.20V;
    User:9-17V
    Lithium battery
    LiFePO4(4S;8S)/Li-NiCoMn(3S;6S)
    Self-consumption
    ≤14mA(12V)
    ≤15mA(24V)
    ● Controller can not auto recognize system voltage when battery type is "lithium battery“, please confirm the
    system voltage before use.
    ※ Without equalize charging when the battery type is "lithium battery".
    ◆ Technical data for 12V system at 25 ℃, twice in 24V system.
    Discharge circuit pressure drop
    ≤0.18V
    Temp. compensation
    -3mV/℃/2V (Lithium battery has no Temp. compensation)
    Grounding
    Common negative
    RS485 communication interface
    5VDC/100mA
    USB interface
    5VDC/2.2A(total)
    Relay interface
    30VDC/1A
    LCD backlight time
    60s(default)
    ※The Temp. compensation coefficient is 0 When the battery type is "lithium battery“ and can not be changed
    Environment parameters
    Working environment temperature
    -25℃~+55℃(with LCD)
    -30℃~+55℃(without LCD)
    Storage temperature range
    -30℃~+70℃
    Humidity range
    ≤95%,(N.C)
    Enclosure
    IP30
    ※ In the working environment temperature range ,Controller can be full load operation .
    Mechanical parameters
    Model
    TRIRON1210N
    TRIRON2210N
    TRIRON3210N
    TRIRON4210N
    Dimension
    135×180.8×47.3mm
    150×216×56.7mm
    158×238.3×62.7mm
    183×256.8×66.7mm
    Terminals
    12AWG(4mm²)
    6AWG(16mm²)
    6AWG(16mm²)
    6AWG(16mm²)
    Net weight
    0.56kg
    0.92kg
    1.35kg
    2.06kg
    Accessories (optional)