-40%
100A 80A 60A 40A MPPT Solar Panel Regulator Charge Controller 12V/24V PV 100V J5
$ 100.31
- Description
- Size Guide
Description
MPPT 40A 60A 80A 100A 12V 24V solar charge controller for maximum 100V solar panel input with two USB 5V output solar controllerMPPT K40A:
12V system : Open circuit voltage≤48V(Voc) Max .PV input Power:520W
24V system: Open circuit voltage≤96V(Voc) Max .PV input Power:1040W
MPPT K60A:
12V system : Open circuit voltage≤48V(Voc) Max .PV input Power:720W
24V system: Open circuit voltage≤96V(Voc) Max .PV input Power:1440W
MPPT K80A:
12V system : Open circuit voltage≤48V(Voc) Max .PV input Power:960W
24V system: Open circuit voltage≤96V(Voc) Max .PV input Power:1920W
MPPT K100A:
12V system : Open circuit voltage≤48V(Voc) Max .PV input Power:1200W
24V system: Open circuit voltage≤96V(Voc) Max .PV input Power:2400W
Overview:
MPPT series solar charge controller is based on an advanced maximum power point tracking (MPPT) technology developed, dedicated to the solar system, the charge controller conversion efficiency up to 98%.
This series MPPT have such advantages:
All the Various Real-time data show on one display ,Convenient user to check
The Solar Panel input voltage up to 100V, suitable for various specifications of solar panel
The power supply uses ultra low power chip ,reducing static standby power consumption ,reduce energy loss
Dual USB 5V Output for phone charging
Support Remote Display
Feature:
Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%.
High quality components, perfecting system performance, with maximum conversion efficiency of 98%.
Ultra-fast tracking speed and guaranteed tracking efficiency.
Wide MPP operating voltage range.
12/24VDC automatically identifying system voltage.
LCD panel display design, dynamically displaying tool‟s operating data and working condition.
Support 3 charging lead-acid battery options: Sealed, Gel, Flooded.
Charge mode: three stages (constant current, constant voltage, floating charge), it prolongs service life of the batteries.
Battery temperature compensation function.
Multiple load work modes
This solar charge controller with three time function.
A: time (night working) B: period (pause) C: time slot (dawn working)
Package Including:
1PCS MPPT Solar Controllers
1PCS User Manual (English)
1PCS Temperature Sensor
Function:
"P" series of an intelligent, multi-purpose solar charge controller
LCD screen display
Battery reverse discharge protection
Simple (and more time control) operation
Battery reverse polarity protection
MPPT charging mode
Battery under voltage protection
Parameter user can reset
Overload, short-circuit protection
A key to open and close the load
Automatic temperature compensation function
A key to restore the factory settings
USB5V charge 2.4A
LCD Operating interface description :
Network Line Interface (RS485) Indicator: Green light represents the battery, green light flashes, indicating that the load is working properly; yellow light indicates solar energy; yellow light flashes, indicating solar energy charging;
Parameter Table:
Model
MPPT 40A
MPPT 60A
Maximum power current
40A
60A
Battery Votlage
12V 24V Auto
Battery float voltage
13.8V(12V system)/27.6V(24V system)
Battery (under voltage) protection
10.6V(12V system)/21.2V(24V system)
Battery (under voltage) recovery voltage
12.6V(12V system)/25.2V(24V system)
Solar Panel Maximum open circuit voltage(Voc)
≤96V(Voc)12V system ; ≤96V(Voc)24V system
Maximum open circuit voltage of the solar panel (Voc)
18V-96V(12V system) / 36V-96V(24V system)
Maximum PV input power
520W(12V system)
1040W(24V system)
750W(12V system)
1500W(24V system)
System load loss
≤13mA
Loop Buck
≤100mV
Operating Temperature
-10°C~60°C
Storeage Temperature
-30°C~70°C
Humidity requirements
≤90%, No condensation
Temperature compensation
-4mV/Cell/°C
Installaton Lin(mm2)
4mm2
6mm2
Installaton Line(AWG)
10(AWG)
10(AWG)
Batery capacity configuration
≥200AH
≥200AH
Model
MPPT 80A
MPPT 100A
Maximum power current
80A
100A
Battery Votlage
12V 24V Auto
Battery float voltage
13.8V(12V system)/27.6V(24V system)
Battery (under voltage) protection
10.6V(12V system)/21.2V(24V system)
Battery (under voltage) recovery voltage
12.6V(12V system)/25.2V(24V system)
Solar Panel Maximum open circuit voltage(Voc)
≤96V(Voc)12V system ; ≤96V(Voc)24V system
Maximum open circuit voltage of the solar panel (Voc)
18V-96V(12V system) / 36V-96V(24V system)
Maximum PV input power
1000W(12V system)
2000W(24V system)
1300W(12V system)
2600W(24V system)
System load loss
≤13mA
Loop Buck
≤100mV
Operating Temperature
-10°C~60°C
Storeage Temperature
-30°C~70°C
Humidity requirements
≤90%, No condensation
Temperature compensation
-4mV/Cell/°C
Installaton Lin(mm2)
8mm2
10mm2
Installaton Line(AWG)
10(AWG)
10(AWG)
Batery capacity configuration
≥300AH
≥300AH
Photo: